From power distribution to photovoltaics, Elettra offers the E880 AEG series of circuit breakers and isolators, with solutions for both alternating current and direct current up to 1,500 V DC.

Protecting a circuit, isolating a line, integrating control and signalling functions: every application requires devices selected on the basis of the system’s characteristics.
The AEG E880 Series, supplied by Elettra, comprises circuit breakers for electrical distribution and solutions designed for direct current, including devices for photovoltaic systems up to 1500 V DC.
The E88050, E880SUC, E880DUC and E880HUC series meet a range of protection and isolation requirements.
Interruttori automatici magnetotermici E88050: da 80 a 125 A, 50 kA a 400Vac
The E88050 thermal-magnetic circuit breakers, part of the Elfa NEXT range, are available in 80, 100 and 125Aratings, with configurations ranging from 1 to 4 poles and trip characteristicsB, C and D.
The series has a breaking capacity of 50 kA in accordance with EN 60947-2.
The E88050 circuit-breakers can also be fitted with residualcurrent devicesand with devices for emergency trip and signalling.

E880SUC circuit breakers: DC applications up to 1500V

AEG E880SUC circuit-breakersare designed for direct current systems up to 1,500 V DC, for use in the photovoltaic sector.
The series comprises rated currents from 16 to 125 A, in a 4-pole configuration (to be connected in series 2 by 2), with an overall width of 6 modulesand a maximum breaking capacity (Icu) of 5 kA.
The E880SUC circuit-breakers can also be fitted with accessories, in particular trip devices for emergency opening and status or trip indication.
E880DUC and E880HUC DC isolators: configurations up to 1500V DC

Alongside circuit breakers, Elettra offers the E880DUC and E880HUC isolators, designed for isolating direct current circuits.
The E880DUC series is available in 32, 63 and 125A ratings, for operating voltages up to 1500V DC, with 4 poles and 6 modules.
The E880HUC series, on the other hand, comprises 32, 63 and 100A ratings, for operating voltages up to 1000V DC, with 2 poles and 3 modules.
These too can be fitted with trip units and auxiliary signalling contacts.
E880 accessories for lever control, indication and locking
Depending on the series and the intended compatibility, the range can be integrated as follows:
• Auxiliary contacts, for signalling the device’s status.
• Trip contacts, for signalling tripping.
• Current-triggered trip units, for emergency tripping via an external control.
• Undervoltage trip units, for emergency tripping in positive-safety circuits.
• Padlock-operated lever locking devices, for locking the lever during maintenance.